40 - 60 Amp Class A GFCI
Industrial Grade - Industrial Tough
60 amp 3 phase gfci, 60A
60 amp 3 phase gfci, 60A
60 amp 3 phase gfci, 60A
60 amp 3 phase gfci, 60A
60 amp 3 phase gfci, 60A
60 amp 3 phase gfci, 60A

40 - 60 Amp Class A GFCI

  • 208 VAC - 3Ø Delta (can be wired as single phase)
  • NEMA 4X wet location rated
  • Enclosure withstands Chemical and U.V. light exposure
  • Double insulated user interface for added safety
  • Industrial design - indoor/outdoor application use
  • Flying leads for electrical circuit splicing
  • 208 VAC - single, and 3Ø Delta
  • NEMA 4X wet location rated
  • Enclosure withstands Chemical and U.V. light exposure
  • Double insulated user interface for added safety
  • Industrial design - indoor/outdoor application use
  • Flying leads for electrical circuit splicing
  • Class-A trip level 5mA +/-1mA
  • Triple indication lights displaying power, contact position, and fault status
  • 1” Conduit hubs for integration to 1” flexible, EMT, PVC or burial conduit
  • UL 943 Listed
  • The LineGard™ 40 - 60 Amp Class A Ground Fault Circuit Interrupter (GFCI) is ideal for both new and existing circuit installations.
  • The LineGard™ 40 - 60 Amp Class A GFCI offers the flexibility of splicing in anywhere within the length of a circuit. This convenience allows the installer to place this GFCI at an accessible location for the end user. Unlike breaker style GFCIs which have limitations of circuit level from the service panel, the LineGard™ 60 Amp Class A GFCI is typically installed at the point of use and therefore has no restrictions to circuit length. The LineGard 60 Amp Class A GFCI can be integrated directly into a circuit or paired in tandem with an approved receptacle.
  • All units have 60” splicing lead wires and 1” NPT conduit fittings for integration to flexible, EMT, PVC, or burial conduit.
  • All LineGard™ 40 - 60 Amp Class A GFCIs are proudly made in the U.S.A. in ISO certified facilities and are UL943 and CSA C22.2 No. 144 listed.
  • Type: Class A
  • Voltage: 208 VAC
  • Operating Voltage Range: 85% to 110% of rating
  • Current: 40A, 50A, 60A
  • Frequency: 60 Hz
  • Trip Level: 5mA +/- 1mA
  • Phase: 3 Phase Delta
  • Response Time: 25ms max at 500 Ω Fault
  • Reset Type: Auto: Output is on immediately upon power up* & Manual: Output is off immediately upon power up*
  • Operating Temperature: -35° C to 50° C (-31° F to 122° F)
  • Enclosure: NEMA 4X wet location rated
  • Latching Mechanism: AC contactor
  • Agency Approval: cULus UL 943; cCSAus certified to CSA-C22.2 No. 144